ABB S202-K4 Miniature Circuit Breaker - 2P - K - 4A 2CDS252001R0337
Circuit breaker is in good cosmetic condition. Kept in a clean environment. Displays signs of normal wear and tear. Pulled from a working environment.
Model
Brand ABB
Description S202-K4 Miniature Circuit Breaker - 2P - K - 4 A
Model S202-K4
Product ID 2CDS252001R0337
Long Description System pro M compact S200 miniature circuit breakers are current limiting. They have two different tripping mechanisms, the delayed thermal tripping mechanism for overload protection and the electromechanic tripping mechanism for short circuit protection. They are available in different characteristics (B,C,D,K,Z), configurations (1P,1P+N,2P,3P,3P+N,4P), breaking capacities (up to 6 kA at 230/400 V AC) and rated currents (up to 63A). All MCBs of the product range S200 comply with IEC/EN 60898-1, IEC/EN 60947-2, UL1077 allowing the use for residential, commercial and industrial applications. Bottom-fitting auxiliary contact can be mounted on S200 to save 50% space.
Technical
*
Standards:
IEC/EN 60898-1
IEC/EN 60947-2
UL 1077
*
Tripping Characteristic:
K
*
Rated Operational Voltage:
acc. to IEC 60898-1 400 V AC
acc. to IEC 60898-1 400 V
acc. to IEC 60947-2 440 V AC
*
Operational Voltage:
Maximum (Incl. Tolerance) 125 V DC
Maximum (Incl. Tolerance) 440 V AC
*
Rated Insulation Voltage (Ui):
acc. to IEC/EN 60664-1 440 V
*
Rated Impulse Withstand Voltage (Uimp):
4 kV
at 2000 m 5 kV
at Sea Level 6.2 kV
*
Dielectric Test Voltage:
50/60 Hz, 1 min: 2 kV
*
Input Voltage Type:
AC/DC
*
Rated Current (In):
4 A
*
Rated Short-Circuit Capacity:
(AC) 6 kA
(DC) 6 kA
(400 V AC) 6 kA
(400 V) 6 kA
*
Rated Ultimate Short-Circuit Breaking Capacity (Icu):
(125 V DC) 10 kA
(230 V AC) 20 kA
(400 V AC) 10 kA
(440 V AC) 10 kA
(48 V DC) 20 kA
(230 V) 20 kA
(400 V) 10 kA
*
Rated Conditional Short-Circuit Current (Inc):
(230 V) 20 kA
(400 V) 20 kA
*
Rated Service Short-Circuit Breaking Capacity (Ics):
(230 V AC) 15 kA
(400 V AC) 7.5 kA
(440 V AC) 7.5 kA
*
Frequency (f):
50 Hz
*
Rated Frequency (f):
50 / 60 Hz
50 ... 60 Hz
*
Power Loss:
3.4 W
at Rated Operating Conditions per Pole 1.7 W
*
Power Supply Connection:
Arbitrary
*
Contact Position Indication:
Red ON / Green OFF
*
Energy Limiting Class:
3
*
Electrical Endurance:
20000 AC cycle
*
Mechanical Endurance:
20000 cycle
*
Number of Poles:
2
*
Number of Protected Poles:
2
*
Overvoltage Category:
III
*
Tightening Torque:
2.8 N·m
*
Mounting Type:
DIN-Rail
*
Screw Terminal Type:
Failsafe Bi-directional Cylinder-lift Terminal
*
Actuator Marking:
I / O
*
Actuator Material:
Insulation Group II, Black, Sealable
*
Housing Material:
Insulation Group II, RAL 7035
*
Mounting on DIN Rail:
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
*
Mounting Position:
any
*
Recommended Screw Driver:
Pozidriv 2
*
Accessories Available:
Yes
*
Connecting Capacity:
Busbar 10 / 10 mm²
Flexible with Ferrule 0.75 ... 25 mm²
Flexible 0.75 ... 25 mm²
Rigid 0.75 ... 35 mm²
Rigid 0.75 ... 35 mm²
Stranded 0.75 ... 35 mm²
*
Installation Size:
acc. to DIN 43880 1
*
Wire Stripping Length:
12.5 mm
*
Terminal Type:
Screw Terminals
SL
Circuit breaker is in good cosmetic condition. Kept in a clean environment. Displays signs of normal wear and tear. Pulled from a working environment.
Model
Brand ABB
Description S202-K4 Miniature Circuit Breaker - 2P - K - 4 A
Model S202-K4
Product ID 2CDS252001R0337
Long Description System pro M compact S200 miniature circuit breakers are current limiting. They have two different tripping mechanisms, the delayed thermal tripping mechanism for overload protection and the electromechanic tripping mechanism for short circuit protection. They are available in different characteristics (B,C,D,K,Z), configurations (1P,1P+N,2P,3P,3P+N,4P), breaking capacities (up to 6 kA at 230/400 V AC) and rated currents (up to 63A). All MCBs of the product range S200 comply with IEC/EN 60898-1, IEC/EN 60947-2, UL1077 allowing the use for residential, commercial and industrial applications. Bottom-fitting auxiliary contact can be mounted on S200 to save 50% space.
Technical
*
Standards:
IEC/EN 60898-1
IEC/EN 60947-2
UL 1077
*
Tripping Characteristic:
K
*
Rated Operational Voltage:
acc. to IEC 60898-1 400 V AC
acc. to IEC 60898-1 400 V
acc. to IEC 60947-2 440 V AC
*
Operational Voltage:
Maximum (Incl. Tolerance) 125 V DC
Maximum (Incl. Tolerance) 440 V AC
*
Rated Insulation Voltage (Ui):
acc. to IEC/EN 60664-1 440 V
*
Rated Impulse Withstand Voltage (Uimp):
4 kV
at 2000 m 5 kV
at Sea Level 6.2 kV
*
Dielectric Test Voltage:
50/60 Hz, 1 min: 2 kV
*
Input Voltage Type:
AC/DC
*
Rated Current (In):
4 A
*
Rated Short-Circuit Capacity:
(AC) 6 kA
(DC) 6 kA
(400 V AC) 6 kA
(400 V) 6 kA
*
Rated Ultimate Short-Circuit Breaking Capacity (Icu):
(125 V DC) 10 kA
(230 V AC) 20 kA
(400 V AC) 10 kA
(440 V AC) 10 kA
(48 V DC) 20 kA
(230 V) 20 kA
(400 V) 10 kA
*
Rated Conditional Short-Circuit Current (Inc):
(230 V) 20 kA
(400 V) 20 kA
*
Rated Service Short-Circuit Breaking Capacity (Ics):
(230 V AC) 15 kA
(400 V AC) 7.5 kA
(440 V AC) 7.5 kA
*
Frequency (f):
50 Hz
*
Rated Frequency (f):
50 / 60 Hz
50 ... 60 Hz
*
Power Loss:
3.4 W
at Rated Operating Conditions per Pole 1.7 W
*
Power Supply Connection:
Arbitrary
*
Contact Position Indication:
Red ON / Green OFF
*
Energy Limiting Class:
3
*
Electrical Endurance:
20000 AC cycle
*
Mechanical Endurance:
20000 cycle
*
Number of Poles:
2
*
Number of Protected Poles:
2
*
Overvoltage Category:
III
*
Tightening Torque:
2.8 N·m
*
Mounting Type:
DIN-Rail
*
Screw Terminal Type:
Failsafe Bi-directional Cylinder-lift Terminal
*
Actuator Marking:
I / O
*
Actuator Material:
Insulation Group II, Black, Sealable
*
Housing Material:
Insulation Group II, RAL 7035
*
Mounting on DIN Rail:
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
*
Mounting Position:
any
*
Recommended Screw Driver:
Pozidriv 2
*
Accessories Available:
Yes
*
Connecting Capacity:
Busbar 10 / 10 mm²
Flexible with Ferrule 0.75 ... 25 mm²
Flexible 0.75 ... 25 mm²
Rigid 0.75 ... 35 mm²
Rigid 0.75 ... 35 mm²
Stranded 0.75 ... 35 mm²
*
Installation Size:
acc. to DIN 43880 1
*
Wire Stripping Length:
12.5 mm
*
Terminal Type:
Screw Terminals
SL