Store Categories
Store Categories
Brands
Brands
- Home
- Computers/Tablets & Networking
- Power-One HN28-3-AG 28V Out Commercial AC/DC Isolated Power Supply 35-4
Power-One HN28-3-AG 28V Out Commercial AC/DC Isolated Power Supply 35-4
$77.17
Product Description
The HN Series Single Output 28 V Commercial AC/DC Isolated Power Supply.
Features:
* World-wide ac input ranges and safety standards
* Industry standard packages
* Commercial UL/CSA TUV/IEC approved- models to UL/CSA 60950; EN/IEC60950-1
* Burn-in with cycling; 3-year warranty
* Capacitors have highest CV & ripple current ratings
* Medical Approved to UL2601-1/60601-1, IEC60601-1 and CSA601.1
* Medical leakage 10 μA
* MTBF 200,000+ hours per MIL-HDBK-217D (most units)
* All electrolytic caps rated at 105°C
* Transformer insulation meets Class F (155°C)
* Exceed FCC and CISPR22, Class B conducted emissions
* RoHS Compliant models available (G suffix)
* Marked to LVD
Specifications:
* Ac Input
** 100, 120 and 240 Vac: +10%, -13%; 215 Vac: +12%, -11%; 47 to 63 Hz. Tolerance for 230 Vac operation is +15%, -10%. Derate output current 10% for 50 Hz operation.
* Dc Output
** See voltage rating chart. Adjustment range ±5% minimum except HA series.
* Line Regulation
** ±0.05% for a 10% change.
* Load Regulation
** ± 0.05% for a 50% load change.
* Output Ripple
** 3 mV +0.05% of output voltage, peak to peak maximum. All "3-terminal regulator" outputs: 3 mV 0.2% peak to peak maximum.
* Transient Response
** <50 microseconds for 50% load change.
* Short Circuit Protection
** Automatic current limit/foldback.
* Overvoltage Protection
** Built-in on all 5 V models, set at 6.2 V ±0.4 V. Other models use optional overvoltage protection.
* Remote Sensing
** Provided on all models; open sense lead protection built-in (except HA & HTAA series).
* Stability
** ±0.05% for 24 hours after warmup.
* Temperature Rating
** 0 to 50°C full rated, derated linearly to 40% at 70°C.
* Temperature Coefficient
** ±0.01%/°C maximum.
* Efficiency
** 5 V units: 45%; 12 and 15 V units: 55%; 20 and 24 V units: 60%.
* Storage
** -40 to +85 °C.
Features:
* World-wide ac input ranges and safety standards
* Industry standard packages
* Commercial UL/CSA TUV/IEC approved- models to UL/CSA 60950; EN/IEC60950-1
* Burn-in with cycling; 3-year warranty
* Capacitors have highest CV & ripple current ratings
* Medical Approved to UL2601-1/60601-1, IEC60601-1 and CSA601.1
* Medical leakage 10 μA
* MTBF 200,000+ hours per MIL-HDBK-217D (most units)
* All electrolytic caps rated at 105°C
* Transformer insulation meets Class F (155°C)
* Exceed FCC and CISPR22, Class B conducted emissions
* RoHS Compliant models available (G suffix)
* Marked to LVD
Specifications:
* Ac Input
** 100, 120 and 240 Vac: +10%, -13%; 215 Vac: +12%, -11%; 47 to 63 Hz. Tolerance for 230 Vac operation is +15%, -10%. Derate output current 10% for 50 Hz operation.
* Dc Output
** See voltage rating chart. Adjustment range ±5% minimum except HA series.
* Line Regulation
** ±0.05% for a 10% change.
* Load Regulation
** ± 0.05% for a 50% load change.
* Output Ripple
** 3 mV +0.05% of output voltage, peak to peak maximum. All "3-terminal regulator" outputs: 3 mV 0.2% peak to peak maximum.
* Transient Response
** <50 microseconds for 50% load change.
* Short Circuit Protection
** Automatic current limit/foldback.
* Overvoltage Protection
** Built-in on all 5 V models, set at 6.2 V ±0.4 V. Other models use optional overvoltage protection.
* Remote Sensing
** Provided on all models; open sense lead protection built-in (except HA & HTAA series).
* Stability
** ±0.05% for 24 hours after warmup.
* Temperature Rating
** 0 to 50°C full rated, derated linearly to 40% at 70°C.
* Temperature Coefficient
** ±0.01%/°C maximum.
* Efficiency
** 5 V units: 45%; 12 and 15 V units: 55%; 20 and 24 V units: 60%.
* Storage
** -40 to +85 °C.